hardware:log [2025/09/01 17:10] – [Sep 01, 2025] fabriciohardware:log [2025/10/31 13:08] (current) – [Sep 26, 2025] fabricio
Line 1: Line 1:
-===== Next Steps / TODO ===== +===== To-Do =====
-  * basel.lan (former strg2). +
-      * Longer cable for adding HDD cage + RAID controller +
-      * add proper password +
-      * setup via Ansible+
   * dl2   * dl2
       * Set up OS;       * Set up OS;
       * Check power usage       * Check power usage
 +  * CMPT2 
 +    * Set up, everything is available.
 ===== Log =====  ===== Log ===== 
 +==== Oct 31, 2025 ====
 +  * Added NVME heatsink to DL2 (removed the old heatsink with lights..)
 +  * Added Quadro GPU to Truenas
 +  * basel.lan: Swapped out 4Gb RAM sticks with 16GB sticks. Now ~122GB RAM available. 32GB and 16GB are incompatible.
 + 
 +==== Sep 26, 2025 ====
 +  * Set RAID 6 with 6 HDDs, and mounted them to storage. Used ext4, single partition. One healthy and one sketchy HDD are available for exchange if one breaks. Moved Raid Controller to PCI Slot 1.
 +
 +
 +==== Sep 22, 2025 ====
 +  * Added 4 HDDs (checked by sebastian) to basel.lan
 +  * Added Simpler 6GB Raid Controller (new) to basel.lan, to be used for the HDD cage now, instead of the 12GB one that was not detected beforehand.
 +
 +==== Sep 15, 2025 ====
 +  * Added SSD for data (1TB Samsung 860 PRO) to CMPT2. Used the 3.5" front entry.
 +
 +==== Sep 11, 2025 ====
 +  * Added RAID controller 'HPE Smart Array P440ar Controller' to basel.lan. Trying out different cable configurations. This will manage the SSD Cage.
 +  * Added RAID Controller P440 to basel.lan. This manages the HDD cage. Checked and working.
 +  * Added Cable from mainboard SAS controller to individual SSDs (no cage, SAS -> multiple SATA) for OS. Set up logical device (i.e. its working).
 +
 +Notes:
 +  * The P440ar can not be accessed from within the UEFI, since it relies on the smart array storage utilities of HP, which require the flash memory of the ilo, which is corrupted and cannot be replaced.
 +  * The idea is to manage it later on within the OS.
  
 ==== Sep 01, 2025 === ==== Sep 01, 2025 ===
Line 15: Line 36:
   * Basel: Added all available 4GB Ram sticks (56GB)   * Basel: Added all available 4GB Ram sticks (56GB)
   * Basel: Added second CPU   * Basel: Added second CPU
-  * Basel: Set up SoftRaid1 for Ubuntu Server 24.04 LTS (separate RAID1 for boot/root/swap) on two 1GB HDDs. Note: Only good tutorial at https://www.youtube.com/watch?v=QQKMlRsEWRE+  * Basel: Set up SoftRaid1 for Ubuntu Server 24.04 LTS (separate RAID1 for boot/root/swap) on two 1TB Samsung HDDs. Note: Only good tutorial at https://www.youtube.com/watch?v=QQKMlRsEWRE
  
 ==== Aug 26, 2025 === ==== Aug 26, 2025 ===
  • hardware/log.1756746603.txt.gz
  • Last modified: 2025/09/01 17:10